Lab Hydrogen Generator: On-Demand Ultra-Pure Hydrogen for GC and GC-MS

HOVOGEN laboratory generators make hydrogen from deionized water the moment an instrument calls for it, so nobody waits on a cylinder delivery. Output is adjustable from 200 to 4,000 ml/min across the LH and LX series, with the purity grade matched to the detector in use. Precision control and layered safety interlocks keep that supply steady through long sequences.

01
Ultra-high purity

LH >99.999%, LX >99.99999% (7-nines). No KOH electrolyte

​

04
Compact & efficient

500×400×505 mm, ≤12 s startup, >77.7% HHV

02
Safer than cylinders

On-demand generation holds <1 L vs ~10,000 L in a 50 L cylinder

​

05
Certified & custom

ISO/CE; configurable flow, pressure & form factor to your instruments.

03
Smart control

Siemens SMART 200 ST20 PLC, TCP/IP remote monitoring, 24/7 unattended

05
Safety mechanisms

Leak alarm, overpressure relief, overheat protection, fault self-diagnosis

China Manufacturer of Lab Hydrogen Generators: LH and LX Series

(Flow Rate: 200-4000 ml/min)

HOVOGEN LH/LX Series scientific PEM hydrogen generator – laboratory hydrogen generator with 200-4000 ml/min flow rate for research applications

Both series come off one in-house PEM platform, assembled and tested at HOVOGEN's own plant. LH covers routine laboratory supply at standard purity; LX adds a further purification stage for work at trace level. Output range, outlet pressure and cabinet format are fixed when you order.

LH Series: Standard-Purity Lab Hydrogen Generator:Routine laboratory duty is what the LH is built for — GC carrier gas, FID fuel gas and general bench supply. Purity holds above 99.999% from 200 ml/min upward, and one unit can feed several instruments on a shared line. A Siemens PLC with touchscreen HMI runs the unit from a benchtop cabinet.

LX Series: High-Purity Hydrogen Generator:Where a detector cannot tolerate oxygen or moisture, the LX takes over. Its purification path lifts purity to 99.99999% (7-nines), and because no KOH enters the gas path there is no alkaline carry-over to contaminate it. GC-MS carrier gas, ICP-MS cell gas and CVD process lines are its usual duty.

Application

HOVOGEN PEM hydrogen fuel cell system – clean electricity generation, zero-emission power, and hydrogen-to-electricity technology for scalable applications

Size the generator to the hungriest instrument and everything else can share the line. The published applications fall into four groups — with THA fuel gas, chemisorption and physisorption measurement, hydrogen fuel cells, weather balloon filling and electronic-nose systems also on the list.

**GC Applications:**
- GC/MS Carrier Gas
- GC Carrier Gas
- GC Fuel Gas
- GC-ELCD & HALL ELCD Reaction Gas

**Spectroscopy Applications:**
- ICP-MS Collision Cell Reaction Gas

**Analyzer Applications:**
- Total Hydrocarbon Analyzer (THA) Fuel Gas
- Chemisorption/Physisorption Measurement Gas

**Other Laboratory Applications:**
- Chemical Vapor Deposition Instrumentation (CVD)

**Auxiliary Deposition Processes:**
- Plasma Cleaning Instrumentation (UCP)
- High-Efficiency Process Gas
- Hydrogenation Reactors
- Hydrogen Fuel Cells
- Weather Balloon Filling
- Electronic Nose (eNOSE)
- 2-D Chromatography
- 3-D Chromatography

Hydrogen Generators for ICP-MS

For spectroscopy work the generator supplies ICP-MS collision cell reaction gas. Hydrogen acts as the reducing agent inside the cell, and holding purity high keeps results reproducible from run to run.

​

​

​

​

Generator or Cylinder? Comparing Hydrogen Supply for Laboratories

What differs is storage, not gas quality. At any moment the generator holds less than a litre of hydrogen; one 50 L cylinder holds roughly 10,000 litres behind 150 bar.

How a Lab Hydrogen Generator Produces Hydrogen On Demand + PEM Electrolysis: No Alkaline Electrolyte in the Loop

image.png

Hydrogen is made where it is used: deionized water passes through the PEM stack, current splits it into hydrogen and oxygen, and nothing sits stored under pressure. No alkali or other reagent is added, and start/stop is fast enough that idle hours draw little power. Electrolysis efficiency runs higher than conventional alkaline technology, so less electricity goes into every litre of gas.

​

The membrane stack electrolyses deionized water directly. Against an alkaline design it reaches working output in about 12 seconds, runs at lower temperature and never handles a corrosive electrolyte. Feed water at ASTM Type II or better (≥1 MΩ·cm) protects both the stack and the purifier.

Confirm the Outlet Pressure Required:

​Output pressure is customizable from 0 to 7 MPa, covering fuel cell work, hydrogen refueling scenarios and laboratory reactors. The setpoint for your application is fixed at order.

Three-Stage Purification with Closed-Loop Control:

Gas leaves the stack wet, then passes molecular sieve, silica gel and a trace-oxygen remover — the combination that makes hydrogen fit for GC-MS and CVD.

 

Behind it, a Siemens SMART 200 ST20 PLC holds pressure, flow and temperature in closed loop and reports over TCP/IP to factory DCS or IoT platforms, which is what makes 24/7 unattended running practical. The touchscreen shows live values, raises fault alarms and exports historical data when a method needs review.

Where and How HOVOGEN Builds Lab Hydrogen Generators

Production follows ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018, and units ship with CE marking. HOVOGEN is a national high-tech enterprise with more than a decade in PEM electrolysis, a portfolio of national invention patents, and a seat on two national hydrogen-production standards: GB/T 37562-2019 and GB/T 37563-2019.

Product Customization

In order to meet the specific needs of customers in different industries and fields, all products can be customized according to requirements. After many years of development, we have accumulated practical experience in many industries. For more details, please check out our projects, or talk to us.

Services and solution

FAQ on the Hovogen Scientific Hydrogen Generator

How much hydrogen flow does a GC laboratory need? Plan for 100–200 cc/min per GC-FID, 200–500 cc/min for several GC systems and 300–1,000 cc/min for GC-MS, with carrier plus fuel duty reaching 4,000 cc/min at the top. The LH/LX range spans 200–4,000 ml/min, so any of these can be covered.

Is a generator safer than a cylinder? Considerably, in storage terms. Gas is produced on demand at low pressure, with automatic shut-off, leak detection and very little volume held inside the unit. Ventilation and written procedures still apply, as with any hydrogen use.

What maintenance does the unit need? Little beyond periodic water refills and the occasional filter change. The no-maintenance design exists to cut both operating cost and instrument downtime.

Which instruments can it connect to? Agilent, Thermo Fisher, Shimadzu, PerkinElmer and Bruker systems, in benchtop, floor-standing or rack-mounted layouts. Properly maintained, the units are rated for 20,000–30,000 operating hours.

Can hydrogen replace helium as carrier gas? For many GC methods it can, once the method is revalidated and linear velocity re-tuned. Hydrogen does react with certain analytes, so method suitability needs checking first.

What purity levels do the LH and LX series reach? LH holds above 99.999% and LX reaches 99.99999% (7-nines), with no KOH electrolyte anywhere in the flow path. The no-maintenance purification system is built to hold those levels for the life of the unit.

For additional details, please consult our FAQ page or contact our support team.

HOVOGEN (Headquarter)

Dongguan, China

Floor 4, Room 411, No. 10, Keji 2nd Road, Zhongke Innovation Plaza, Songshan Lake High-Tech Industrial Development Zone, Dongguan City, Guangdong, China 523000
Tel/WhatsApp: +86-15916927868 Email: sales@hovogen.com

HOVOGEN (Manufacture Base) Zhuzhou, China

Add:Unit 1208, Building C1, Xinma Jingu Phase III, No. 266 Xinma South Road, Majiahe Street, Tianyuan District, Zhuzhou City, Hunan

HOVOGEN (Office)

HongKong, China

Add:Unit 18, 10/F

Fortune Commercial Building

362 Sha Tsui Road

Tsuen Wan 

Hong Kong

Tel: +852-8402 1602

HOVOGEN (Japan Branch)

Tokyo, Japan

東京都八王子市長沼町104-2ヒルサイドテラス1-4

bottom of page